[Home]  [Headlines]  [Latest Articles]  [Latest Comments]  [Post]  [Mail]  [Sign-in]  [Setup]  [Help]  [Register] 

"Trump's Tariff Play Smart, Strategic, Working"

"Leftists Make Desperate Attempt to Discredit Photo of Abrego Garcia's MS-13 Tattoos. Here Are Receipts"

"Trump Administration Freezes $2 Billion After Harvard Refuses to Meet Demands"on After Harvard Refuses to Meet Demands

"Doctors Committing Insurance Fraud to Conceal Trans Procedures, Texas Children’s Whistleblower Testifies"

"Left Using '8647' Symbol for Violence Against Trump, Musk"

KawasakiÂ’s new rideable robohorse is straight out of a sci-fi novel

"Trade should work for America, not rule it"

"The Stakes Couldn’t Be Higher in Wisconsin’s Supreme Court Race – What’s at Risk for the GOP"

"How Trump caught big-government fans in their own trap"

‘Are You Prepared for Violence?’

Greek Orthodox Archbishop gives President Trump a Cross, tells him "Make America Invincible"

"Trump signs executive order eliminating the Department of Education!!!"

"If AOC Is the Democratic Future, the Party Is Even Worse Off Than We Think"

"Ending EPA Overreach"

Closest Look Ever at How Pyramids Were Built

Moment the SpaceX crew Meets Stranded ISS Crew

The Exodus Pharaoh EXPLAINED!

Did the Israelites Really Cross the Red Sea? Stunning Evidence of the Location of Red Sea Crossing!

Are we experiencing a Triumph of Orthodoxy?

Judge Napolitano with Konstantin Malofeev (Moscow, Russia)

"Trump Administration Cancels Most USAID Programs, Folds Others into State Department"

Introducing Manus: The General AI Agent

"Chinese Spies in Our Military? Straight to Jail"

Any suggestion that the USA and NATO are "Helping" or have ever helped Ukraine needs to be shot down instantly

"Real problem with the Palestinians: Nobody wants them"

ACDC & The Rolling Stones - Rock Me Baby

Magnus Carlsen gives a London System lesson!

"The Democrats Are Suffering Through a Drought of Generational Talent"

7 Tactics Of The Enemy To Weaken Your Faith

Strange And Biblical Events Are Happening

Every year ... BusiesT casino gambling day -- in Las Vegas

Trump’s DOGE Plan Is Legally Untouchable—Elon Musk Holds the Scalpel

Palestinians: What do you think of the Trump plan for Gaza?

What Happens Inside Gaza’s Secret Tunnels? | Unpacked

Hamas Torture Bodycam Footage: "These Monsters Filmed it All" | IDF Warfighter Doron Keidar, Ep. 225

EXPOSED: The Dark Truth About the Hostages in Gaza

New Task Force Ready To Expose Dark Secrets

Egypt Amasses Forces on Israel’s Southern Border | World War 3 About to Start?

"Trump wants to dismantle the Education Department. Here’s how it would work"

test

"Federal Workers Concerned That Returning To Office Will Interfere With Them Not Working"

"Yes, the Democrats Have a Governing Problem – They Blame America First, Then Govern Accordingly"

"Trump and His New Frenemies, Abroad and at Home"

"The Left’s Sin Is of Omission and Lost Opportunity"

"How Trump’s team will break down the woke bureaucracy"

Pete Hegseth will be confirmed in a few minutes

"Greg Gutfeld Cooks Jessica Tarlov and Liberal Media in Brilliant Take on Trump's First Day"

"They Gave Trump the Center, and He Took It"

French doors

America THEN and NOW in 65 FASCINATING Photos


Status: Not Logged In; Sign In

911
See other 911 Articles

Title: WTC 7 Building; Fuel Systems for Emergency Power
Source: NIST reports online (in non-copyable pdf form)
URL Source: http://wtc.nist.gov/reports_october05.htm
Published: Jul 22, 2007
Author: NIST w/_Jim excerpting and editing
Post Date: 2007-07-22 19:28:50 by _Jim
Keywords: 911 troofers, WTC7 fuel systems, WTC debunking
Views: 974
Comments: 1

I took the liberty of extracting, excerpting and editing from the original document: NIST NCSTAR 1-1J, "WTC Investigation" the following details concerning the make up of the emergency power fuel distribution system that was located inside WTC bldg number 7 (WTC 7).

It is advantageous to know the details of this system such that when various known 'fire' scenarios are examined they may be understood knowing the systems and potential fuel sources that are/were present in WTC 7.

The following is presented for educational purposes only.


WTC 7 contained two independently supplied and operated fuel systems for emergency power:

1) the Base Building system and
2) the Salomon Brothers system.


1) The Base Building system consisted of four subsystems:

- the Silverstein sub-system (original system),
- the Ambassador Construction sub-system,
- the American Express sub-system, and
- the Mayor's Office of Emergency Management sub-system.

The Ambassador Construction and American Express sub-systems were supplied with fuel from the original Base Building storage tanks installed below the loading dock.

The Mayor?s Office sub-system contained its own storage tank that was filled from the original system tanks.

The other system (the Salmon Brothers system), was supplied by a separate set of fuel storage tanks, also located below the loading dock.

The systems had differing design features with each system operating independently. The two systems combined with all of the sub-systems, contained more than an estimated 43,000 gal of fuel, assuming all tanks were filled near capacity. Since the owners had contracts with fuel delivery services to maintain the tanks full at all times, this assumption is considered reasonable.

E.1 BASE BUILDING SYSTEM

The Silverstein system was installed in 1987.

The system contained two 12,000 gal capacity storage tanks located below the 1st floor loading dock. The tanks supplied no. 2 diesel fuel to a duplex fuel oil pump set located in the 1st floor Fuel Oil Pump Room situated between the west banks of passenger elevators. The pumps supplied fuel to a 275 gal capacity day tank (1) in the 5th floor Generator Room, which supplied fuel to two 900 kW generators. The fuel Oil Return (FOR) pipes ran in parallel with the Fuel Oil Supply (FOS) pipes returning fuel back to the day tank and storage tanks.

In 1994, the Silverstein system was modified for the Ambassador Construction project. The Base Building system was extended by tapping off the existing FOS pipe to the duplex pump set in the 1st floor

Footnote (1) A day tank is a small-capacity fuel storage tank located near the generator(s) and kept full by a transfer pump from a main tank at or below grade. The BCNYC limits fuel supplies to no more than one 275 gal (maximum) day tank on any floor above the 1st.

Fuel Oil Pump Room. The pump supplied fuel to the engine mounted day tank (50 gal capacity) of the 125 kW generator located on the 9th floor. The FOR pipe ran back to the existing FOR at the 1st floor.

Again in 1994, the Silverstein system was modified for the American Express project. The Base Building system was extended by tapping off the existing FOS suction pipe and adding another duplex pump set in the 1st floor Fuel Oil Pump Room. A 275 gal day tank was added on the 8th floor, which supplied fuel to the 350 kW generator.

In 1999, the Silverstein system was modified for the Mayor?s Office of Emergency Management project. The system added two additional duplex pump sets. The 1st pump set was used to fill a new 6,000 gal above ground storage tank on the 1st floor. The second pump set was used to supply fuel from the new storage tank to the new 275 gal day tank and three 500 kW generators on the 7th floor.

The four Base Building sub-systems were similarly designed, but were independently operated by the fuel pump set controllers for each system. The sub-systems included many similar devices, such as antisyphon valves, foot valves, fusible link gate valves, solenoid valves, fuel level switches, rupture basins and leak detectors, all performing specific operations. Although each sub-system was not designed exactly like the other, the four sub-systems operated and performed similarly. Each sub-system operated based on the liquid level in the day tanks. Each sub-system control panel (four total) started and stopped the respective pump set by the liquid level switch in each day tank.

The various fuel devices listed above provided increased assurance that unwanted fuel discharge would not occur. The devices listed above would have prevented, in most if not all scenarios, unwanted fuel discharge unto the floor below. The devices were installed to isolate fuel from open piping breaks, prevent backflow and drainage of fuel unto the floor below and shut off the pump set to prevent fuel flow.

E.2 SALOMON BROTHERS SYSTEM

In 1990, a second fuel oil distribution system was installed for the Salomon Brothers project. The fuel for the system was supplied by two 6,000 gal storage tanks located under the loading dock. FOS pipes ran to the duplex pump set on the 1st floor. The FOS discharge pipes ran up to the 5th floor supplying fuel to nine 1,750 kW generators. The FOS discharge pipe ended at a valve rig where the FOR pipe started and ran back to the pump set and storage tanks.

The Salomon Brothers fuel system had a similar but slightly different design than the Base Building system.

Similar to the Base Building system, the pump set provided fuel from two underground storage tanks. However, there was already a day tank on the 5th floor associated with the base system and the BCNYC did not permit more than one day tank per floor. Thus, the Salomon Brothers system used a continuously pressurized fuel supply piping system without a day tank. The fuel pressure in the FOS discharge piping was maintained by a liquid level switch and back pressure regulator in the 5th floor valve rig. The liquid level switch started and stopped the pump set in accordance with the liquid level in the FOS discharge pipe. The pump was powered from the generators such that any time any one generator was running, the pump was powered.


Caveat/Legal Notice:

Any use of this material, including any legal action or in any lawsuit, are subject to the provisions as specified in 15 USC 281a; as amended by P.L. 107-231.

Any readers are are urged to do their own research and study pursuant to doing "due diligence" on this subject matter or any other matter relating to this matter.

Views expressed by this poster are not those of any particular agency or bureau, nor are these views represented to be part of any US, state or local gov't bureau e.g. NIST, PANYNJ, NYC, et cetera, but are soley those of the individual poster.


Post Comment   Private Reply   Ignore Thread  


TopPage UpFull ThreadPage DownBottom/Latest

#1. To: All (#0)

Bump

_Jim  posted on  2007-07-24   20:22:36 ET  Reply   Trace   Private Reply  


TopPage UpFull ThreadPage DownBottom/Latest

[Home]  [Headlines]  [Latest Articles]  [Latest Comments]  [Post]  [Mail]  [Sign-in]  [Setup]  [Help]  [Register] 

Please report web page problems, questions and comments to webmaster@libertysflame.com